Boiler Room Checklist
A boiler room inspection checklist helps facility teams, property managers, and service technicians check the condition of boiler rooms, boilers, gauges, piping, valves, safety devices, burners, gas lines, exhaust vents, pumps, drainage, fire safety equipment, and visible maintenance issues.
This checklist is useful for apartment buildings, offices, schools, hotels, warehouses, healthcare facilities, industrial sites, and other managed properties where boiler performance and safety directly affect heating, hot water, operations, and occupant comfort.
With TARGPatrol, boiler room inspections can be completed as scheduled digital checks or route-based maintenance tasks. Technicians can scan a QR code in the boiler room, attach photos, record readings, report defects, create work orders, assign responsible users, and track corrective actions until the issue is resolved.
Property / facility name
Property address
Building / floor / zone
Boiler room location
Boiler ID / asset number
Boiler type
Photo of boiler room overview
Boiler room is accessible
Boiler room door opens properly
Boiler room door is secured
Required signage is visible
Room lighting is working
Room ventilation appears adequate
No unauthorized storage in boiler room
Required clearance around boiler is maintained
Floor is clean and dry
No immediate safety hazards observed
General boiler room notes
Boiler appears operational
Boiler exterior is not damaged
Boiler panels and covers are closed
No unusual noise observed
No unusual vibration observed
No burning smell or unusual odor observed
No visible overheating signs observed
Boiler condition issue notes
Photo of boiler condition
Pressure gauge is readable
Pressure appears within normal operating range
Temperature gauge is readable
Temperature appears within normal operating range
Gauge glass / display is clean and readable, if present
Pressure reading
Temperature reading
Gauge issue notes
Photo of gauges / display
No visible water leaks around boiler
No visible leaks from pipes or fittings
No water pooling on floor
No corrosion on visible boiler parts
No rust stains or water damage observed
Leak / corrosion issue location
Photo of leak or corrosion issue
Piping appears secure
Pipe insulation is intact where required
No loose or unsupported pipes observed
Valves are accessible
Valves are labeled where required
No valve damage observed
Piping / valve issue notes
Photo of piping or valve condition
Safety relief valve is present
Safety relief valve is not blocked
Discharge pipe is installed and directed safely, if visible
Expansion tank appears intact, if present
Low-water cutoff appears present, if applicable
Emergency shutoff is accessible
Safety device issue notes
Photo of safety device condition
Burner area appears clean, if applicable
Burner cover is secure, if applicable
Flame appearance is normal, if visible
No soot buildup observed
No scorch marks observed
Ignition system appears functional, if checked
Burner issue notes
Photo of burner area
Gas line area appears safe, if applicable
No gas odor detected
Gas shutoff valve is accessible, if applicable
Gas piping appears undamaged where visible
Fuel storage area appears safe, if applicable
Fuel / gas issue notes
Photo of gas or fuel area
Flue / exhaust vent is connected
Flue / exhaust vent is not blocked
No visible damage to flue or venting
No soot or discoloration around venting
Combustion air openings are clear
Ventilation / exhaust issue notes
Photo of flue or exhaust condition
Electrical disconnect is accessible
Electrical panel / controls are closed and secure
No exposed wiring observed
No damaged switches, covers, or conduits observed
No signs of electrical overheating observed
Electrical issue notes
Photo of electrical condition
Pump appears operational, if present
Pump area is clean and dry
No pump leaks observed
No unusual pump noise or vibration observed
Pump connections appear secure
Pump issue notes
Photo of pump condition
Condensate drain is clear, if applicable
Floor drain is clear
No drain blockage observed
No backflow or standing water observed
Drainage issue notes
Photo of drainage condition
Carbon monoxide alarm is present where required
Carbon monoxide alarm appears functional when tested
Smoke detector is present where required
Fire extinguisher is accessible, if required
Fire extinguisher inspection tag appears current, if checked
Fire safety issue notes
Photo of fire / CO safety equipment
Boiler room temperature is acceptable
No excessive heat buildup observed
No excessive moisture or condensation observed
No mold or mildew visible
No pest activity observed
Environmental condition notes
Photo of environmental issue
Maintenance tag / service record is visible, if provided
Previous boiler issue was reviewed, if applicable
Previous corrective action appears completed
Open boiler issue still requires follow-up
Previous work order number
Photo of service tag or previous issue area
Boiler room issue found
Issue location
Issue description
Issue type
Priority: low / medium / high / urgent
Repair required
Further technician inspection required
Responsible person
Target completion date
Work order number
Photo of boiler room issue
Temporary control applied
Unsafe equipment was turned off, if required
Area was restricted, if unsafe
Property manager / facility manager notified
Boiler service contractor notified
Follow-up inspection required
Photo after temporary control
Inspection completed
Property passed inspection
Final status
Final comments