Electrical Equipment Safety Checklist
An Electrical Equipment Maintenance Checklist helps maintenance and EHS teams turn scheduled work into a clear, repeatable process. Instead of relying on memory, it lays out actionable items across LOTO and absence-of-voltage verification, enclosure condition, labeling and single-line accuracy, conductors and terminations, grounding/bonding, protection devices, motors and starters, VFDs/drives, transformers, UPS/batteries, and thermal inspections. Each item is simple to confirm — from “terminals torqued, no discoloration” to “RCD/GFCI trip time within spec” — so critical details aren’t missed.
For plants and warehouses, this checklist strengthens electrical safety, cuts unplanned downtime, and supports compliance with internal standards and local regulations. Used regularly, it creates a maintenance rhythm where clearances are preserved, wear and hotspots are detected early, and protection settings stay current.
Supervisors gain a clean audit trail. The checklist records who checked what and when, documents defects, and links corrective actions to owners and due dates — invaluable during audits, insurance reviews, and incident investigations.
The template works both as a printable PDF and in the TARGPatrol mobile app. Teams can attach photos, enter measurements, and add comments in real time. Mixed answer types — [Flag], [Number], [Media], [Text] — make it easy to capture conditions, numerical readings (voltage, torque, resistance, temperature, vibration), visual evidence, and context in one place. Regular use improves reliability, speeds maintenance, and keeps your facility inspection-ready.
Work order / CMMS ID recorded
Equipment ID / asset tag matches records
SOPs / drawings available at point of use
LOTO procedure posted and understood
Energy sources identified (elec/hyd/pneu/thermal)
LOTO applied (locks/tags/hasp)
Zero-energy verified (try/verify)
Stored energy released (capacitors/springs)
Absence-of-voltage test (V)
Photo: lockout points / nameplate
Enclosure doors/hinges/seals intact
IP/NEMA rating suits environment
No dust/moisture/chemical ingress
Ambient within spec
Photo: enclosure exterior
Circuit IDs/labels/arc-flash labels legible
Single-line updated and accessible
Nameplates readable
Torque settings available
Photo: representative labels
Cable insulation free of cuts/abrasion
Bend radius/supports acceptable
Lugs/terminals tight (no discoloration)
Torque on main terminations (N·m)
Ferrules/markers correct
Photo: terminations before/after
Grounding conductor present/continuous
Bonding jumpers at doors/hinges
Resistance to ground (Ω)
Ground bus connections clean/tight
Photo: ground points
Breakers/fuses rating & type correct
No overheating/arcing traces
Trip unit settings match study
RCD/GFCI trip time (ms)
Photo: protection device details
Pushbuttons/selectors/indicators work
Contactors/relays contact condition OK
PLC/HMI shows no active faults
Backup taken / versions noted
Photo: HMI/PLC screen
Cable trays loading within limits
Power/control separation maintained
Conduit fittings tight, penetrations sealed
Photo: trays/conduit runs
Motor nameplate vs starter/drive settings
Insulation resistance (MΩ @ test V)
Bearing temperature (°C/°F)
Vibration overall (mm/s or in/s)
Photo: motor/starter
VFD filters/ventilation clean (if present)
DC bus voltage (V)
Fault log reviewed (recurring trips?)
Photo: VFD display/params
Transformer condition (leaks/odor/noise)
Secondary voltage (V)
Photo: transformer nameplate/terminals
UPS/batteries: float voltage per block (V)
Charger output (V/A)
Terminals corrosion treated
Photo: battery/UPS terminals
Thermal imaging completed (if permitted)
Hottest connection temperature (°C/°F)
ΔT vs ambient (°C/°F)
Photo: annotated IR hotspot
Dust/debris removed, heatsinks/fans cleaned
Signs of rust/corrosion treated
Moisture mitigation (heaters/desiccants) present
Photo: before/after cleaning
Covers/guards reinstalled & torqued
Control circuit functional test pass
Interlocks/E-Stops verified
No-load current (A)
Photo: powered status indicators
Parts used (PN/qty)
Outstanding defects & corrective actions/owners
Next PM due (date or run hours)
Overall status (In Service / Limited / OOS)
Photo: posted maintenance summary